Facility

Certified Metal Craft is a 32,000 sq. ft. Brazing and Heat Treating Facility.

FURNACE

TEMPERATURE

WORK ZONE

ATMOSPHERE

NOTES

VACUUM FURNACES
V-1 600° – 2450o F 15″W x 10″H x 24″D VACUUM / ARGON / NITROGEN
V-2 900° – 2450o F 48″W x 48″H x 63″D VACUUM / ARGON
V-3 900° – 2450o F 54″W x 54″H x 58″D VACUUM / ARGON
V-4 900° – 2450o F 36″W x 36″H x 48″D VACUUM / ARGON
V-5 900° – 2450o F 36″W x 36″H x 48″D VACUUM / ARGON
V-6 900° – 2400o F 48″W x 48″H x 48″D VACUUM / ARGON
V-7 900° – 2400o F 48″W x 48″H x 48″D VACUUM / ARGON
V-8 900° – 2400o F 38″W x 30″H x 60″D VACUUM / ARGON
ALUMINUM DROP BOTTOM FURNACE
A-1 400° – 1100o F 60″W x 60″H x 60″D AIR 6
A-2 170° – 500o F 72″W x 72″H x 72″D AIR
A-3 170° – 500o F 72″W x 72″H x 72″D AIR
CRYOGENIC PROCESSOR
C-1 -320o - +300o F 60″W x 36″H x 36″D 2500# LOADS
RECIRCULATING AIR FURNACES
F-2 400° – 1200o F 15.5″ DIA.x 16″D AIR
F-3 200° – 850o F 24″W x 16″H x 18″D AIR
F-4 200° – 750o F 48″W x 72″H x 48″D AIR
F-6 200° – 850o F 24″W x 16″H x 18″D AIR
F-7 400° – 1200o F 27″ DIA.x 30″D AIR
F-10 500° – 1400o F 24″W x 20″H x 48″D AIR
F-14 1400° – 2250o F 24″W x 18″H x 42″D AIR / ARGON / HYDROGEN
F-16 700° – 1500o F 72″W x 72″H x 96″D AIR
F-17 700° – 1400o F 48″W x 48″H x 72″D AIR / ARGON / NITROGEN
ENDOTHERMIC FURNACES
E – 11 1400° – 1950o F 24″W x 24″H x 33″D CARBURIZING / ENDO / ARGON
E – 12 1400° – 1950o F 24″W x 24″H x 33″D CARBURIZING / ENDO
SALT BATHS
SALT – 5 300° – 1100o F 12″ DIA. x 12" Deep LOW TEMP SALT  
SALT – 5 1400° – 1700o F 17″ DIA. x 38″Deep NEUTRAL SALT
INSPECTION EQUIPMENT
NEWAGE INDENTRON / WILSON 3JR, 4JR, 5JS / AMES 4-4 PORTABLE / 3000DL CONDUCTIVITY METER
PRODUCTION BLASTING
VIKING 600 RUBBER BELT BLAST MILL – 600 LB LOAD / SAND & BEAD BLASTING CAPABILITIES
CERTIFIED METAL CRAFT

SINCE 1969 / 32,000 SQ. FT. / 30 EMPLOYEES / AEROSPACE & COMMERCIAL

Notes

  1. FURNACE CAPABLE OF POSITIVE PRESSURE QUENCH.
  2. FURNACE CAPABLE OF PARTIAL PRESSURE OPERATION.
  3. QUENCH CAPABILITIES ARE AIR, OIL, OR WATER
  4. QUENCH CAPABILITIES ARE ENDO ATMOSPHERE, OR OIL.
  5. QUENCH CAPABILITIES ARE HYDROGEN, ARGON, WATER, OIL, OR AIR.
  6. WATER OR POLYGLYCOL QUENCH.